Champion 201532 published runtime
- Gasoline: 15 hours at 25% load on 4.5 gallons
- Propane (LP): 18 hours (load not stated) on a 20 lb propane tank
Champion's product description gives these figures. The spec table on the same page lists different ones (18 hours on gasoline and 16 hours on propane at 1/4 load), so we use the description's wording. Champion does not state a load for the 18-hour propane figure, so the calculator shows it as published but does not estimate other loads from it.
Verified specifications
- Manufacturer
- Champion
- Model
- 6500W Dual Fuel Inverter with CO Shield
- Model number
- 201532
- Generator type
- Inverter / Dual Fuel
- Gasoline: running
- 5,250 watts
- Gasoline: starting / max
- 6,500 watts
- Gasoline: tank
- 4.5 gallons
- Gasoline: published runtime
- 15 hours at 25% load on 4.5 gallons
- Propane (LP): running
- 4,725 watts
- Propane (LP): starting / max
- 6,500 watts
- Propane (LP): published runtime
- 18 hours at load not stated on a 20 lb propane cylinder
- Engine
- Champion 224cc
- Displacement
- 224cc
- Weight
- 105.4 lb
- Noise
- 64 dB(A) at 23 ft
- CO safety
- CO Shield
- Outlets
- (2) 120V 20A 5-20R duplex; (1) 120V 30A TT-30R RV; (1) 120/240V 21.9A L14-30R locking; (1) 12V 8A automotive-style DC
Source: Champion Power Equipment — 201532 product page — View Champion Specifications ↗
Specifications verified: September 28, 2026
Which model this page covers
This page covers model 201532, the 6500W Dual Fuel Inverter with CO Shield. Champion sells several similarly named 6500W models with different specs; they are not mixed in.
Manufacturer figures vs. our estimates
Only the runtimes listed above are Champion's own published figures. When your load and fuel amount exactly match one of them, the calculator labels the result Manufacturer Published Runtime. Loads between published figures are labeled Estimated from Manufacturer Data, and loads outside the published range are labeled Extrapolated with a wider range. Those are GeneratorRuntime estimates, not Champion specifications.
What the Champion 201532's outlets let you connect
Based on the outlets Champion lists for this model. An outlet's amp rating is the most that one outlet can carry; the total from all outlets together can never exceed the generator's rated running watts.
- A 30-amp 120/240V four-prong locking outlet: the usual connection for a 30-amp manual transfer switch or interlock inlet installed by an electrician, and the outlet needed for 240V equipment such as a well pump.
- A TT-30R RV outlet: plugs straight into a 30-amp travel-trailer cord without an adapter.
- Low-voltage DC or USB ports for charging small devices without an inverter adapter.
Outlet types are from Champion's product page or owner's manual. Powering home circuits requires a properly installed transfer switch or interlock — have a licensed electrician do it. Never plug a generator into a wall outlet ("backfeeding"): it can electrocute utility workers and neighbors and start fires.
Outage fuel planning for the Champion 201532
Dividing each of Champion's published runtimes by the fuel it was measured on gives an average burn rate. Each row assumes the generator runs continuously, around the clock, at exactly the load of that published figure: 24 hours = rate × 24, 72 hours = rate × 72, refills per day = 24 ÷ published runtime. These are GeneratorRuntime calculations from Champion's figures, not Champion specifications. Real outage use with appliances cycling on and off, or running the generator in intervals, usually needs less.
| Published point | Burn rate | 24 hours | 72 hours | Refills / day |
|---|---|---|---|---|
| Gasoline, 25% load: 15 h on 4.5 gal | ≈ 0.30 gal/h | ≈ 7.2 gal | ≈ 21.6 gal | ≈ 1.6 |
| Propane (LP), load not stated: 18 h on 20 lb | ≈ 1.11 lb/h | ≈ 26.7 lb | ≈ 80.0 lb | ≈ 1.3 |
Champion 201532 compared with similar generators
Figures below are each manufacturer's own published numbers for its first-listed fuel. Runtimes are shown at 25% load where the manufacturer publishes one; rows marked "different load" are not directly comparable. Tank sizes differ too, so use the calculator with each model for a like-for-like estimate at your load.
| Model | Running | Fuels | Tank | Published runtime |
|---|---|---|---|---|
| Champion 6500W Dual Fuel Inverter with CO Shield (201532) | 5,250 W | Gasoline / Propane (LP) | 4.5 gal | 15 h @ 25% load |
| WEN DF680iX | 5,100 W | Gasoline / Propane (LP) | 2.9 gal | 6.1 h @ 50% load (different load) |
| FIRMAN WT05571 Tri-Fuel Inverter (WT05571) | 5,500 W | Gasoline / Propane (LP) / Natural gas | 5.3 gal | 14.5 h @ 25% load |
| Honda EU7000iS | 5,500 W | Gasoline | 5.1 gal | 16 h @ 25% load |
| Champion 5500W Dual Fuel Inverter (201243) | 4,000 W | Gasoline / Propane (LP) | 3.7 gal | 20 h @ 25% load |
What Champion's published data doesn't cover
For the Champion 201532, the verified manufacturer data we used does not include:
- a gasoline runtime at 50% load
- a propane (lp) runtime at 25% load (estimates below the lowest published load are extrapolated)
- a propane (lp) runtime at 50% load
- the load its propane (lp) runtime was measured at
We leave these blank rather than guess. If you have an official Champion figure we're missing, tell us via the feedback link below.
The Champion 201532's CO Shield feature is not a substitute for safe placement — see the carbon monoxide warning above.
Champion 201532 FAQ
›How long will a Champion 201532 run on gasoline?
Champion's published figure: 15 hours at 25% load on 4.5 gallons.
›How long will a Champion 201532 run on propane (lp)?
Champion's published figure: 18 hours (load not stated) on a 20 lb propane tank.
›Which Champion 201532 does this page cover?
model 201532, the 6500W Dual Fuel Inverter with CO Shield. Champion sells several similarly named 6500W models with different specs; they are not mixed in. Output: gasoline 5,250 watts running / 6,500 watts starting; propane (lp) 4,725 watts running / 6,500 watts starting.
Similar generators
- WEN DF680iX — 5,100 watts running
- FIRMAN WT05571 Tri-Fuel Inverter (WT05571) — 5,500 watts running
- Honda EU7000iS — 5,500 watts running
- Champion 5500W Dual Fuel Inverter (201243) — 4,000 watts running
- Champion 4500W Dual Fuel Inverter (201531) — 3,250 watts running
- Champion 4000W Dual Fuel Inverter (201050) — 3,000 watts running
- Champion 2500W Dual Fuel Inverter (201530) — 1,850 watts running
Browse the full Generator Runtime Database or use the main Generator Runtime Calculator.