GP7500E Dual Fuel published runtime
- Gasoline: 10 hours at 50% load on 7.9 gallons
- Propane (LP): 5 hours at 50% load on a 20 lb propane tank
From Generac's official product information, checked September 28, 2026.
Verified specifications
- Manufacturer
- Generac
- Model
- GP7500E Dual Fuel with COsense
- Model number
- 8011-2
- Model codes
- GP7500E / DF / 80112 / G0080112
- Generator type
- Conventional / Dual Fuel
- Gasoline: running
- 7,500 watts
- Gasoline: starting / max
- 9,400 watts
- Gasoline: tank
- 7.9 gallons
- Gasoline: published runtime
- 10 hours at 50% load on 7.9 gallons
- Propane (LP): running
- 6,800 watts
- Propane (LP): starting / max
- 8,500 watts
- Propane (LP): published runtime
- 5 hours at 50% load on a 20 lb propane cylinder
- Voltage
- 120/240V
- Frequency
- 60 Hz
- Engine
- Generac 420cc OHV
- Displacement
- 420cc
- Weight
- 204 lb
- Starting system
- Electric start, pull start
- CO safety
- COsense
- Outlets
- (2) 120V 20A 5-20R GFCI duplex; (1) 120/240V 30A L14-30R twist-lock
Source: Generac GP7500E Dual Fuel spec sheet, model 8011-2 — View Generac Specifications ↗
Specifications verified: September 28, 2026
Which model this page covers
This page covers the current GP7500E Dual Fuel with COsense, model 8011-2 (49-state). The older gasoline-only GP7500E and the 50-state 8011-0 are not mixed in.
Manufacturer figures vs. our estimates
Only the runtimes listed above are Generac's own published figures. When your load and fuel amount exactly match one of them, the calculator labels the result Manufacturer Published Runtime. Loads between published figures are labeled Estimated from Manufacturer Data, and loads outside the published range are labeled Extrapolated with a wider range. Those are GeneratorRuntime estimates, not Generac specifications.
What the GP7500E Dual Fuel's outlets let you connect
Based on the outlets Generac lists for this model. An outlet's amp rating is the most that one outlet can carry; the total from all outlets together can never exceed the generator's rated running watts.
- A 30-amp 120/240V four-prong locking outlet: the usual connection for a 30-amp manual transfer switch or interlock inlet installed by an electrician, and the outlet needed for 240V equipment such as a well pump.
- GFCI-protected household outlets: test the GFCI before each use, as the manual instructs.
Outlet types are from Generac's product page or owner's manual. Powering home circuits requires a properly installed transfer switch or interlock — have a licensed electrician do it. Never plug a generator into a wall outlet ("backfeeding"): it can electrocute utility workers and neighbors and start fires.
Outage fuel planning for the GP7500E Dual Fuel
Dividing each of Generac's published runtimes by the fuel it was measured on gives an average burn rate. Each row assumes the generator runs continuously, around the clock, at exactly the load of that published figure: 24 hours = rate × 24, 72 hours = rate × 72, refills per day = 24 ÷ published runtime. These are GeneratorRuntime calculations from Generac's figures, not Generac specifications. Real outage use with appliances cycling on and off, or running the generator in intervals, usually needs less.
| Published point | Burn rate | 24 hours | 72 hours | Refills / day |
|---|---|---|---|---|
| Gasoline, 50% load: 10 h on 7.9 gal | ≈ 0.79 gal/h | ≈ 19.0 gal | ≈ 56.9 gal | ≈ 2.4 |
| Propane (LP), 50% load: 5 h on 20 lb | ≈ 4.00 lb/h | ≈ 96.0 lb | ≈ 288.0 lb | ≈ 4.8 |
GP7500E Dual Fuel compared with similar generators
Figures below are each manufacturer's own published numbers for its first-listed fuel. Runtimes are shown at 50% load where the manufacturer publishes one; rows marked "different load" are not directly comparable. Tank sizes differ too, so use the calculator with each model for a like-for-like estimate at your load.
| Model | Running | Fuels | Tank | Published runtime |
|---|---|---|---|---|
| Generac GP7500E Dual Fuel with COsense (8011-2) | 7,500 W | Gasoline / Propane (LP) | 7.9 gal | 10 h @ 50% load |
| Champion 7500W Electric Start Dual Fuel (201281) | 7,500 W | Gasoline / Propane (LP) | 7.7 gal | 10 h @ 50% load |
| Generac GP8000E with COsense (EFI) (8929) | 8,000 W | Gasoline | 7.9 gal | 12 h @ 50% load |
| FIRMAN T08073 Tri-Fuel (T08073) | 8,000 W | Gasoline / Propane (LP) / Natural gas | 8 gal | 10.5 h @ 50% load |
| Generac GP6500 with COsense (7680) | 6,500 W | Gasoline | 7.9 gal | 11.5 h @ 50% load |
What Generac's published data doesn't cover
For the GP7500E Dual Fuel, the verified manufacturer data we used does not include:
- a gasoline runtime at 25% load (estimates below the lowest published load are extrapolated)
- a propane (lp) runtime at 25% load (estimates below the lowest published load are extrapolated)
- a noise rating
We leave these blank rather than guess. If you have an official Generac figure we're missing, tell us via the feedback link below.
The GP7500E Dual Fuel's COsense feature is not a substitute for safe placement — see the carbon monoxide warning above.
GP7500E Dual Fuel FAQ
›How long will a GP7500E Dual Fuel run on gasoline?
Generac's published figure: 10 hours at 50% load on 7.9 gallons.
›How long will a GP7500E Dual Fuel run on propane (lp)?
Generac's published figure: 5 hours at 50% load on a 20 lb propane tank.
›Which GP7500E Dual Fuel does this page cover?
the current GP7500E Dual Fuel with COsense, model 8011-2 (49-state). The older gasoline-only GP7500E and the 50-state 8011-0 are not mixed in. Output: gasoline 7,500 watts running / 9,400 watts starting; propane (lp) 6,800 watts running / 8,500 watts starting.
Similar generators
- Champion 7500W Electric Start Dual Fuel (201281) — 7,500 watts running
- Generac GP8000E with COsense (EFI) (8929) — 8,000 watts running
- FIRMAN T08073 Tri-Fuel (T08073) — 8,000 watts running
- Generac GP6500 with COsense (7680) — 6,500 watts running
- Generac GP5500E (G0081500) — 5,500 watts running