Generac iQ3500 published runtime
Generac's spec sheet for the iQ3500 with COsense (model 7723) lists 14.1 hours at 25% load and 8.9 hours at 50% load on a full 2.6-gallon tank. Because both points are published, loads between 25% and 50% are estimated from Generac's own data.
Verified specifications
- Manufacturer
- Generac
- Model
- iQ3500 with COsense
- Model number
- 7723
- Model codes
- 7723-1 / 7723-2 / 7723-3
- Generator type
- Inverter
- Gasoline: running
- 3,000 watts
- Gasoline: starting / max
- 3,500 watts
- Gasoline: tank
- 2.6 gallons
- Gasoline: published runtime
- 14.1 hours at 25% load on 2.6 gallons
- Gasoline: published runtime
- 8.9 hours at 50% load on 2.6 gallons
- Voltage
- 120V
- Frequency
- 60 Hz
- Displacement
- 212cc
- Weight
- 109.1 lb
- Starting system
- PowerDial and electric start (battery included)
- CO safety
- COsense
- Outlets
- (1) 120V 20A 5-20R duplex; (1) 120V 30A L5-30R twist-lock; 5V DC USB (1A / 2.1A)
Source: Generac iQ3500 (7723) spec sheet — View Generac Specifications ↗
Specifications verified: September 28, 2026
How much gas does the Generac iQ3500 use?
- At 25% load: 2.6 gal ÷ 14.1 h ≈ 0.18 gallons per hour
- At 50% load: 2.6 gal ÷ 8.9 h ≈ 0.29 gallons per hour
These are our calculations from Generac's published tank size and runtimes, not Generac figures.
Manufacturer figures vs. our estimates
Only the runtimes listed above are Generac's own published figures. When your load and fuel amount exactly match one of them, the calculator labels the result Manufacturer Published Runtime. Loads between published figures are labeled Estimated from Manufacturer Data, and loads outside the published range are labeled Extrapolated with a wider range. Those are GeneratorRuntime estimates, not Generac specifications.
What the Generac iQ3500's outlets let you connect
Based on the outlets Generac lists for this model. An outlet's amp rating is the most that one outlet can carry; the total from all outlets together can never exceed the generator's rated running watts.
- No 120/240V outlet is listed, so it cannot power 240V equipment or feed both legs of a home transfer switch.
- A 120V 30-amp locking outlet: for a heavy single 120V load or a 30-amp RV with the correct adapter.
- Low-voltage DC or USB ports for charging small devices without an inverter adapter.
Outlet types are from Generac's product page or owner's manual. Powering home circuits requires a properly installed transfer switch or interlock — have a licensed electrician do it. Never plug a generator into a wall outlet ("backfeeding"): it can electrocute utility workers and neighbors and start fires.
Outage fuel planning for the Generac iQ3500
Dividing each of Generac's published runtimes by the fuel it was measured on gives an average burn rate. Each row assumes the generator runs continuously, around the clock, at exactly the load of that published figure: 24 hours = rate × 24, 72 hours = rate × 72, refills per day = 24 ÷ published runtime. These are GeneratorRuntime calculations from Generac's figures, not Generac specifications. Real outage use with appliances cycling on and off, or running the generator in intervals, usually needs less.
| Published point | Burn rate | 24 hours | 72 hours | Refills / day |
|---|---|---|---|---|
| Gasoline, 25% load: 14.1 h on 2.6 gal | ≈ 0.18 gal/h | ≈ 4.4 gal | ≈ 13.3 gal | ≈ 1.7 |
| Gasoline, 50% load: 8.9 h on 2.6 gal | ≈ 0.29 gal/h | ≈ 7.0 gal | ≈ 21.0 gal | ≈ 2.7 |
Generac iQ3500 compared with similar generators
Figures below are each manufacturer's own published numbers for its first-listed fuel. Runtimes are shown at 25% load where the manufacturer publishes one; rows marked "different load" are not directly comparable. Tank sizes differ too, so use the calculator with each model for a like-for-like estimate at your load.
| Model | Running | Fuels | Tank | Published runtime |
|---|---|---|---|---|
| Generac iQ3500 with COsense (7723) | 3,000 W | Gasoline | 2.6 gal | 14.1 h @ 25% load |
| Predator 3500 Super Quiet Inverter (71358) | 3,000 W | Gasoline | 2.33 gal | 11 h @ 25% load |
| Champion 4000W Dual Fuel Inverter (201050) | 3,000 W | Gasoline / Propane (LP) | 1.54 gal | 10 h @ 25% load |
| WEN DF360iX | 2,900 W | Gasoline / Propane (LP) | 1.53 gal | 5 h @ 50% load (different load) |
| Honda EU3000iS | 2,800 W | Gasoline | 3.4 gal | 19.6 h @ 25% load |
What Generac's published data doesn't cover
For the Generac iQ3500, the verified manufacturer data we used does not include:
- a noise rating
We leave these blank rather than guess. If you have an official Generac figure we're missing, tell us via the feedback link below.
The Generac iQ3500's COsense feature is not a substitute for safe placement — see the carbon monoxide warning above.
Generac iQ3500 FAQ
›How long will a Generac iQ3500 run on a full tank?
Generac's spec sheet lists 14.1 hours at 25% of rated load and 8.9 hours at 50% of rated load on the 2.6-gallon tank.
›What is the Generac iQ3500 runtime at full load?
Generac does not publish a full-load runtime. The calculator extrapolates beyond 50% load and labels those results "Extrapolated" with a wider range.
›How many watts does the Generac iQ3500 produce?
3,000 watts running and 3,500 watts starting, according to Generac.
›Which iQ3500 model does this page cover?
Model 7723 with COsense (configurations 7723-1, 7723-2 and 7723-3). The older model 7127 without COsense is a different configuration and is not covered here.
Similar generators
- Predator 3500 Super Quiet Inverter (71358) — 3,000 watts running
- Champion 4000W Dual Fuel Inverter (201050) — 3,000 watts running
- WEN DF360iX — 2,900 watts running
- Honda EU3000iS — 2,800 watts running
Browse the full Generator Runtime Database or use the main Generator Runtime Calculator.