Predator 2500 published runtime
- Gasoline: 10.2 hours at 25% load on 1.3 gallons
Harbor Freight's current product page gives 10.2 hours at 25% load with ESC on. The item 72010 owner's manual lists 12 hours for the same condition; we use the product-page figure because it is Harbor Freight's current, repeated number.
Verified specifications
- Manufacturer
- Predator
- Model
- 2500 Watt Super Quiet Inverter
- Model number
- 72010
- Model codes
- Predator / 2500 / item / 72010
- Generator type
- Inverter
- Gasoline: running
- 2,000 watts
- Gasoline: starting / max
- 2,500 watts
- Gasoline: tank
- 1.3 gallons
- Gasoline: published runtime
- 10.2 hours at 25% load on 1.3 gallons
- Voltage
- 120V
- Engine
- Predator 98cc
- Displacement
- 98cc
- Weight
- 46 lb
- Noise
- 58 dB(A) at 25% load
- Starting system
- Recoil
- CO safety
- CO SECURE
- Outlets
- (2) 120V 20A 5-20R; (1) 12V 8A DC; USB-A, USB-C (30W PD)
Source: Harbor Freight — Predator 2500 product page, item 72010 — View Harbor Freight Specifications ↗
Specifications verified: September 28, 2026
Which model this page covers
This page covers the 2500 Watt Super Quiet Inverter with CO SECURE, item 72010 (49-state). The California version (item 73422) is a separate item and is not covered. It is also a different generator from the Predator 2000.
Manufacturer figures vs. our estimates
Only the runtimes listed above are Harbor Freight's own published figures. When your load and fuel amount exactly match one of them, the calculator labels the result Manufacturer Published Runtime. Loads between published figures are labeled Estimated from Manufacturer Data, and loads outside the published range are labeled Extrapolated with a wider range. Those are GeneratorRuntime estimates, not Harbor Freight specifications.
What the Predator 2500's outlets let you connect
Based on the outlets Harbor Freight lists for this model. An outlet's amp rating is the most that one outlet can carry; the total from all outlets together can never exceed the generator's rated running watts.
- No 120/240V outlet is listed, so it cannot power 240V equipment or feed both legs of a home transfer switch.
- Low-voltage DC or USB ports for charging small devices without an inverter adapter.
Outlet types are from Harbor Freight's product page or owner's manual. Powering home circuits requires a properly installed transfer switch or interlock — have a licensed electrician do it. Never plug a generator into a wall outlet ("backfeeding"): it can electrocute utility workers and neighbors and start fires.
Outage fuel planning for the Predator 2500
Dividing each of Harbor Freight's published runtimes by the fuel it was measured on gives an average burn rate. Each row assumes the generator runs continuously, around the clock, at exactly the load of that published figure: 24 hours = rate × 24, 72 hours = rate × 72, refills per day = 24 ÷ published runtime. These are GeneratorRuntime calculations from Harbor Freight's figures, not Harbor Freight specifications. Real outage use with appliances cycling on and off, or running the generator in intervals, usually needs less.
| Published point | Burn rate | 24 hours | 72 hours | Refills / day |
|---|---|---|---|---|
| Gasoline, 25% load: 10.2 h on 1.3 gal | ≈ 0.13 gal/h | ≈ 3.1 gal | ≈ 9.2 gal | ≈ 2.4 |
Predator 2500 compared with similar generators
Figures below are each manufacturer's own published numbers for its first-listed fuel. Runtimes are shown at 25% load where the manufacturer publishes one; rows marked "different load" are not directly comparable. Tank sizes differ too, so use the calculator with each model for a like-for-like estimate at your load.
| Model | Running | Fuels | Tank | Published runtime |
|---|---|---|---|---|
| Predator 2500 Watt Super Quiet Inverter (72010) | 2,000 W | Gasoline | 1.3 gal | 10.2 h @ 25% load |
| WEN 56235iX | 1,900 W | Gasoline | 1.06 gal | 5.7 h @ 50% load (different load) |
| Champion 2500W Dual Fuel Inverter (201530) | 1,850 W | Gasoline / Propane (LP) | 1.05 gal | 11.5 h @ 25% load |
| Honda EU2200i | 1,800 W | Gasoline | 0.95 gal | 8.1 h @ 25% load |
| Predator 2000 Super Quiet Inverter (71343) | 1,600 W | Gasoline | 1.27 gal | 12 h @ 25% load |
What Harbor Freight's published data doesn't cover
For the Predator 2500, the verified manufacturer data we used does not include:
- a gasoline runtime at 50% load
We leave these blank rather than guess. If you have an official Harbor Freight figure we're missing, tell us via the feedback link below.
The Predator 2500's CO SECURE feature is not a substitute for safe placement — see the carbon monoxide warning above.
Predator 2500 FAQ
›How long will a Predator 2500 run on gasoline?
Harbor Freight's published figure: 10.2 hours at 25% load on 1.3 gallons.
›Which Predator 2500 does this page cover?
the 2500 Watt Super Quiet Inverter with CO SECURE, item 72010 (49-state). The California version (item 73422) is a separate item and is not covered. It is also a different generator from the Predator 2000. Output: gasoline 2,000 watts running / 2,500 watts starting.
Similar generators
- WEN 56235iX — 1,900 watts running
- Champion 2500W Dual Fuel Inverter (201530) — 1,850 watts running
- Honda EU2200i — 1,800 watts running
- Predator 2000 Super Quiet Inverter (71343) — 1,600 watts running
- Predator 3500 Super Quiet Inverter (71358) — 3,000 watts running
- Predator 5000 Dual-Fuel Super Quiet Inverter (71367) — 3,900 watts running
Browse the full Generator Runtime Database or use the main Generator Runtime Calculator.