DuroMax XP13000EH published runtime
- Gasoline: 17 hours at 25% load and 8 hours at 50% load on 8.3 gallons
- Propane: 13 hours at 25% load and 6 hours at 50% load (propane quantity not stated)
This page covers the DuroMax XP13000EH only — not the XP13000HX, XP13000HXT, or other 13,000-watt DuroMax models.
Specifications for the XP13000EH have varied across DuroMax documentation and revisions. This entry reflects DuroMax's currently published XP13000EH specifications, checked September 28, 2026.
Verified specifications
- Manufacturer
- DuroMax
- Model
- XP13000EH
- Generator type
- Conventional / Dual Fuel
- Gasoline: running
- 10,500 watts
- Gasoline: starting / max
- 13,000 watts
- Gasoline: tank
- 8.3 gallons
- Gasoline: published runtime
- 17 hours at 25% load on 8.3 gallons
- Gasoline: published runtime
- 8 hours at 50% load on 8.3 gallons
- Propane (LP): running
- 9,975 watts
- Propane (LP): starting / max
- 12,350 watts
- Propane (LP): published runtime
- 13 hours at 25% load on propane amount not stated
- Propane (LP): published runtime
- 6 hours at 50% load on propane amount not stated
- Engine
- DuroMax 4-stroke, forced-air cooled
- Displacement
- 500cc
- Dry weight
- 234 lb
- Weight
- 248 lb
- Noise
- 74 dB(A)
- CO safety
- CO sensor shutdown
- Outlets
- (2) 5-20R (GFCI); (1) L5-30R; (1) L14-30R; (1) 14-50R 50A
Source: DuroMax Power Equipment — current XP13000EH product page — View DuroMax Specifications ↗
Specifications verified: September 28, 2026
How much gas does the XP13000EH use?
- At 25% load: 8.3 gal ÷ 17 h ≈ 0.49 gallons per hour
- At 50% load: 8.3 gal ÷ 8 h ≈ 1.04 gallons per hour
These are our calculations from DuroMax's published tank size and runtimes, not DuroMax figures. We do not calculate propane use per hour because DuroMax does not state the propane quantity.
Manufacturer figures vs. our estimates
Only the runtimes listed above are DuroMax's own published figures. When your load and fuel amount exactly match one of them, the calculator labels the result Manufacturer Published Runtime. Loads between published figures are labeled Estimated from Manufacturer Data, and loads outside the published range are labeled Extrapolated with a wider range. Those are GeneratorRuntime estimates, not DuroMax specifications.
What the DuroMax XP13000EH's outlets let you connect
Based on the outlets DuroMax lists for this model. An outlet's amp rating is the most that one outlet can carry; the total from all outlets together can never exceed the generator's rated running watts.
- A 14-50R 50-amp outlet: accepts a 50-amp RV cord or a 50-amp generator cord to a properly installed transfer switch or inlet box. The 50-amp rating is the outlet's limit, not the generator's — power through it is still capped at the generator's rated running watts.
- A 30-amp 120/240V four-prong locking outlet: the usual connection for a 30-amp manual transfer switch or interlock inlet installed by an electrician, and the outlet needed for 240V equipment such as a well pump.
- A 120V 30-amp locking outlet: for a heavy single 120V load or a 30-amp RV with the correct adapter.
- GFCI-protected household outlets: test the GFCI before each use, as the manual instructs.
Outlet types are from DuroMax's product page or owner's manual. Powering home circuits requires a properly installed transfer switch or interlock — have a licensed electrician do it. Never plug a generator into a wall outlet ("backfeeding"): it can electrocute utility workers and neighbors and start fires.
Outage fuel planning for the DuroMax XP13000EH
Dividing each of DuroMax's published runtimes by the fuel it was measured on gives an average burn rate. Each row assumes the generator runs continuously, around the clock, at exactly the load of that published figure: 24 hours = rate × 24, 72 hours = rate × 72, refills per day = 24 ÷ published runtime. These are GeneratorRuntime calculations from DuroMax's figures, not DuroMax specifications. Real outage use with appliances cycling on and off, or running the generator in intervals, usually needs less.
| Published point | Burn rate | 24 hours | 72 hours | Refills / day |
|---|---|---|---|---|
| Gasoline, 25% load: 17 h on 8.3 gal | ≈ 0.49 gal/h | ≈ 11.7 gal | ≈ 35.2 gal | ≈ 1.4 |
| Gasoline, 50% load: 8 h on 8.3 gal | ≈ 1.04 gal/h | ≈ 24.9 gal | ≈ 74.7 gal | ≈ 3.0 |
DuroMax XP13000EH compared with similar generators
Figures below are each manufacturer's own published numbers for its first-listed fuel. Runtimes are shown at 50% load where the manufacturer publishes one; rows marked "different load" are not directly comparable. Tank sizes differ too, so use the calculator with each model for a like-for-like estimate at your load.
| Model | Running | Fuels | Tank | Published runtime |
|---|---|---|---|---|
| DuroMax XP13000EH | 10,500 W | Gasoline / Propane (LP) | 8.3 gal | 8 h @ 50% load |
| Westinghouse WGen10500DFc (10523) | 10,500 W | Gasoline / Propane (LP) | 9.5 gal | 9.5 h @ 50% load |
| DuroMax XP13000HX | 10,500 W | Gasoline / Propane (LP) | 8.3 gal | 8.5 h @ 50% load |
| DuroMax XP13000HXT | 10,500 W | Gasoline / Propane (LP) / Natural gas | 8.3 gal | 8.5 h @ 50% load |
| Predator 13000 Tri-Fuel (71386) | 10,000 W | Gasoline / Propane (LP) / Natural gas | 10.7 gal | 12.1 h @ 50% load |
What DuroMax's published data doesn't cover
For the DuroMax XP13000EH, the verified manufacturer data we used does not include:
- the propane tank size its propane runtime was measured on
We leave these blank rather than guess. If you have an official DuroMax figure we're missing, tell us via the feedback link below.
The DuroMax XP13000EH's CO sensor shutdown feature is not a substitute for safe placement — see the carbon monoxide warning above.
DuroMax XP13000EH FAQ
›How long will a DuroMax XP13000EH run on gasoline?
DuroMax lists 17 hours at 25% load and 8 hours at 50% load on the 8.3-gallon tank.
›How long will a DuroMax XP13000EH run on propane?
DuroMax lists 13 hours at 25% load and 6 hours at 50% load, but does not state the propane quantity. DuroMax suggests a 40 lb minimum propane tank. Because the tank size behind these figures is unknown, the calculator does not scale them to other tank sizes.
›How many watts does the DuroMax XP13000EH produce?
Gasoline: 10,500 watts running / 13,000 watts peak. Propane: 9,975 watts running / 12,350 watts peak.
›Is this the same as the XP13000HX or XP13000HXT?
No. This page covers only the DuroMax XP13000EH. The XP13000HX, XP13000HXT and other 13,000-watt DuroMax models have different specifications.
Similar generators
- Westinghouse WGen10500DFc (10523) — 10,500 watts running
- DuroMax XP13000HX — 10,500 watts running
- DuroMax XP13000HXT — 10,500 watts running
- Predator 13000 Tri-Fuel (71386) — 10,000 watts running
- DuroMax XP12000EH — 9,500 watts running
- DuroMax XP15000HXT — 12,000 watts running
- DuroMax XP17500HX — 13,750 watts running
Browse the full Generator Runtime Database or use the main Generator Runtime Calculator.