XP13000HXT published runtime
- Gasoline: 17 hours at 25% load on 8.3 gallons; 8.5 hours at 50% load on 8.3 gallons
- Propane (LP): 13 hours at 25% load on an unstated amount of propane; 6.5 hours at 50% load on an unstated amount of propane
- Natural gas: no runtime limit published — runs as long as the gas supply continues
DuroMax does not say how much propane its propane runtimes were measured on (it suggests a 40 lb tank minimum), so the calculator shows the published propane hours but does not estimate other tank sizes. On natural gas, runtime depends on a continued gas supply at 6–9 inches of water column; DuroMax lists 225,000 BTU per hour at full load.
Verified specifications
- Manufacturer
- DuroMax
- Model
- XP13000HXT
- Generator type
- Conventional / Tri-Fuel
- Gasoline: running
- 10,500 watts
- Gasoline: starting / max
- 13,000 watts
- Gasoline: tank
- 8.3 gallons
- Gasoline: published runtime
- 17 hours at 25% load on 8.3 gallons
- Gasoline: published runtime
- 8.5 hours at 50% load on 8.3 gallons
- Propane (LP): running
- 10,000 watts
- Propane (LP): starting / max
- 12,500 watts
- Propane (LP): published runtime
- 13 hours at 25% load on propane amount not stated
- Propane (LP): published runtime
- 6.5 hours at 50% load on propane amount not stated
- Natural gas: running
- 9,000 watts
- Natural gas: starting / max
- 11,250 watts
- Engine
- DuroMax 4-stroke OHV, forced-air cooled
- Displacement
- 500cc
- Dry weight
- 240 lb
- Weight
- 246 lb
- Noise
- 74 dB(A)
- Starting system
- Push-button electric, remote, recoil
- CO safety
- CO sensor shutdown
- Outlets
- (4) 5-20R (GFCI); (1) L5-30R; (1) L14-30R; (1) 14-50R 50A
Source: DuroMax Power Equipment — current XP13000HXT product page — View DuroMax Specifications ↗
Specifications verified: September 28, 2026
Which model this page covers
This page covers the tri-fuel XP13000HXT only — not the XP13000HX or XP13000EH. Figures come only from DuroMax's current XP13000HXT page.
Manufacturer figures vs. our estimates
Only the runtimes listed above are DuroMax's own published figures. When your load and fuel amount exactly match one of them, the calculator labels the result Manufacturer Published Runtime. Loads between published figures are labeled Estimated from Manufacturer Data, and loads outside the published range are labeled Extrapolated with a wider range. Those are GeneratorRuntime estimates, not DuroMax specifications.
What the XP13000HXT's outlets let you connect
Based on the outlets DuroMax lists for this model. An outlet's amp rating is the most that one outlet can carry; the total from all outlets together can never exceed the generator's rated running watts.
- A 14-50R 50-amp outlet: accepts a 50-amp RV cord or a 50-amp generator cord to a properly installed transfer switch or inlet box. The 50-amp rating is the outlet's limit, not the generator's — power through it is still capped at the generator's rated running watts.
- A 30-amp 120/240V four-prong locking outlet: the usual connection for a 30-amp manual transfer switch or interlock inlet installed by an electrician, and the outlet needed for 240V equipment such as a well pump.
- A 120V 30-amp locking outlet: for a heavy single 120V load or a 30-amp RV with the correct adapter.
- GFCI-protected household outlets: test the GFCI before each use, as the manual instructs.
Outlet types are from DuroMax's product page or owner's manual. Powering home circuits requires a properly installed transfer switch or interlock — have a licensed electrician do it. Never plug a generator into a wall outlet ("backfeeding"): it can electrocute utility workers and neighbors and start fires.
Outage fuel planning for the XP13000HXT
Dividing each of DuroMax's published runtimes by the fuel it was measured on gives an average burn rate. Each row assumes the generator runs continuously, around the clock, at exactly the load of that published figure: 24 hours = rate × 24, 72 hours = rate × 72, refills per day = 24 ÷ published runtime. These are GeneratorRuntime calculations from DuroMax's figures, not DuroMax specifications. Real outage use with appliances cycling on and off, or running the generator in intervals, usually needs less.
| Published point | Burn rate | 24 hours | 72 hours | Refills / day |
|---|---|---|---|---|
| Gasoline, 25% load: 17 h on 8.3 gal | ≈ 0.49 gal/h | ≈ 11.7 gal | ≈ 35.2 gal | ≈ 1.4 |
| Gasoline, 50% load: 8.5 h on 8.3 gal | ≈ 0.98 gal/h | ≈ 23.4 gal | ≈ 70.3 gal | ≈ 2.8 |
XP13000HXT compared with similar generators
Figures below are each manufacturer's own published numbers for its first-listed fuel. Runtimes are shown at 50% load where the manufacturer publishes one; rows marked "different load" are not directly comparable. Tank sizes differ too, so use the calculator with each model for a like-for-like estimate at your load.
| Model | Running | Fuels | Tank | Published runtime |
|---|---|---|---|---|
| DuroMax XP13000HXT | 10,500 W | Gasoline / Propane (LP) / Natural gas | 8.3 gal | 8.5 h @ 50% load |
| DuroMax XP13000EH | 10,500 W | Gasoline / Propane (LP) | 8.3 gal | 8 h @ 50% load |
| Westinghouse WGen10500DFc (10523) | 10,500 W | Gasoline / Propane (LP) | 9.5 gal | 9.5 h @ 50% load |
| DuroMax XP13000HX | 10,500 W | Gasoline / Propane (LP) | 8.3 gal | 8.5 h @ 50% load |
| Predator 13000 Tri-Fuel (71386) | 10,000 W | Gasoline / Propane (LP) / Natural gas | 10.7 gal | 12.1 h @ 50% load |
What DuroMax's published data doesn't cover
For the XP13000HXT, the verified manufacturer data we used does not include:
- the propane tank size its propane runtime was measured on
- any natural gas runtime
We leave these blank rather than guess. If you have an official DuroMax figure we're missing, tell us via the feedback link below.
The XP13000HXT's CO sensor shutdown feature is not a substitute for safe placement — see the carbon monoxide warning above.
XP13000HXT FAQ
›How long will a XP13000HXT run on gasoline?
DuroMax's published figure: 17 hours at 25% load on 8.3 gallons; 8.5 hours at 50% load on 8.3 gallons.
›How long will a XP13000HXT run on propane (lp)?
DuroMax's published figure: 13 hours at 25% load on an unstated amount of propane; 6.5 hours at 50% load on an unstated amount of propane.
›How long will a XP13000HXT run on natural gas?
DuroMax's published figure: no runtime limit published — runs as long as the gas supply continues.
›Which XP13000HXT does this page cover?
the tri-fuel XP13000HXT only — not the XP13000HX or XP13000EH. Figures come only from DuroMax's current XP13000HXT page. Output: gasoline 10,500 watts running / 13,000 watts starting; propane (lp) 10,000 watts running / 12,500 watts starting; natural gas 9,000 watts running / 11,250 watts starting.
Similar generators
- DuroMax XP13000EH — 10,500 watts running
- Westinghouse WGen10500DFc (10523) — 10,500 watts running
- DuroMax XP13000HX — 10,500 watts running
- Predator 13000 Tri-Fuel (71386) — 10,000 watts running
- DuroMax XP12000EH — 9,500 watts running
- DuroMax XP15000HXT — 12,000 watts running
- DuroMax XP17500HX — 13,750 watts running