iGen12000DFc published runtime
- Gasoline: 19 hours at 25% load on 7.9 gallons; 11 hours at 50% load on 7.9 gallons
- Propane (LP): 9 hours at 25% load on a 20 lb propane tank; 5 hours at 50% load on a 20 lb propane tank
From Westinghouse's official product information, checked September 28, 2026.
Verified specifications
- Manufacturer
- Westinghouse
- Model
- iGen12000DFc
- Generator type
- Inverter / Dual Fuel
- Gasoline: running
- 9,000 watts
- Gasoline: starting / max
- 12,000 watts
- Gasoline: tank
- 7.9 gallons
- Gasoline: published runtime
- 19 hours at 25% load on 7.9 gallons
- Gasoline: published runtime
- 11 hours at 50% load on 7.9 gallons
- Propane (LP): running
- 8,100 watts
- Propane (LP): starting / max
- 11,000 watts
- Propane (LP): published runtime
- 9 hours at 25% load on a 20 lb propane cylinder
- Propane (LP): published runtime
- 5 hours at 50% load on a 20 lb propane cylinder
- Voltage
- 120/240V
- Engine
- Westinghouse 457cc OHV 4-stroke
- Displacement
- 457cc
- Dry weight
- 189 lb
- Noise
- 64 dB(A)
- Starting system
- Electric, remote, recoil
- CO safety
- CO sensor with automatic shutdown
- Outlets
- (1) 120V 5-20R duplex (GFCI); (1) 120/240V 14-50R; (1) 120/240V L14-30R
Source: Westinghouse — iGen12000DFc product page — View Westinghouse Specifications ↗
Specifications verified: September 28, 2026
Which model this page covers
This page covers the iGen12000DFc dual fuel inverter only — not the iGen11000DFc. Westinghouse's spec table lists it as dual fuel (gasoline and propane); this page does not assign a natural gas rating.
Manufacturer figures vs. our estimates
Only the runtimes listed above are Westinghouse's own published figures. When your load and fuel amount exactly match one of them, the calculator labels the result Manufacturer Published Runtime. Loads between published figures are labeled Estimated from Manufacturer Data, and loads outside the published range are labeled Extrapolated with a wider range. Those are GeneratorRuntime estimates, not Westinghouse specifications.
What the iGen12000DFc's outlets let you connect
Based on the outlets Westinghouse lists for this model. An outlet's amp rating is the most that one outlet can carry; the total from all outlets together can never exceed the generator's rated running watts.
- A 14-50R 50-amp outlet: accepts a 50-amp RV cord or a 50-amp generator cord to a properly installed transfer switch or inlet box. The 50-amp rating is the outlet's limit, not the generator's — power through it is still capped at the generator's rated running watts.
- A 30-amp 120/240V four-prong locking outlet: the usual connection for a 30-amp manual transfer switch or interlock inlet installed by an electrician, and the outlet needed for 240V equipment such as a well pump.
- GFCI-protected household outlets: test the GFCI before each use, as the manual instructs.
Outlet types are from Westinghouse's product page or owner's manual. Powering home circuits requires a properly installed transfer switch or interlock — have a licensed electrician do it. Never plug a generator into a wall outlet ("backfeeding"): it can electrocute utility workers and neighbors and start fires.
Outage fuel planning for the iGen12000DFc
Dividing each of Westinghouse's published runtimes by the fuel it was measured on gives an average burn rate. Each row assumes the generator runs continuously, around the clock, at exactly the load of that published figure: 24 hours = rate × 24, 72 hours = rate × 72, refills per day = 24 ÷ published runtime. These are GeneratorRuntime calculations from Westinghouse's figures, not Westinghouse specifications. Real outage use with appliances cycling on and off, or running the generator in intervals, usually needs less.
| Published point | Burn rate | 24 hours | 72 hours | Refills / day |
|---|---|---|---|---|
| Gasoline, 25% load: 19 h on 7.9 gal | ≈ 0.42 gal/h | ≈ 10.0 gal | ≈ 29.9 gal | ≈ 1.3 |
| Gasoline, 50% load: 11 h on 7.9 gal | ≈ 0.72 gal/h | ≈ 17.2 gal | ≈ 51.7 gal | ≈ 2.2 |
| Propane (LP), 25% load: 9 h on 20 lb | ≈ 2.22 lb/h | ≈ 53.3 lb | ≈ 160.0 lb | ≈ 2.7 |
| Propane (LP), 50% load: 5 h on 20 lb | ≈ 4.00 lb/h | ≈ 96.0 lb | ≈ 288.0 lb | ≈ 4.8 |
iGen12000DFc compared with similar generators
Figures below are each manufacturer's own published numbers for its first-listed fuel. Runtimes are shown at 25% load where the manufacturer publishes one; rows marked "different load" are not directly comparable. Tank sizes differ too, so use the calculator with each model for a like-for-like estimate at your load.
| Model | Running | Fuels | Tank | Published runtime |
|---|---|---|---|---|
| Westinghouse iGen12000DFc | 9,000 W | Gasoline / Propane (LP) | 7.9 gal | 19 h @ 25% load |
| Westinghouse iGen11000DFc (11023) | 9,000 W | Gasoline / Propane (LP) | 7.92 gal | 17 h @ 25% load |
| Predator 11,500 Watt Tri-Fuel Super Quiet Inverter (72614) | 9,000 W | Gasoline / Propane (LP) / Natural gas | 6.8 gal | 14 h @ 25% load |
| Predator 9500 Super Quiet Inverter (71365) | 7,600 W | Gasoline | 6.6 gal | 18.5 h @ 25% load |
| Westinghouse iGen5000DFc | 3,900 W | Gasoline / Propane (LP) | 3.4 gal | 18 h @ 25% load |
The iGen12000DFc's CO sensor with automatic shutdown feature is not a substitute for safe placement — see the carbon monoxide warning above.
iGen12000DFc FAQ
›How long will a iGen12000DFc run on gasoline?
Westinghouse's published figure: 19 hours at 25% load on 7.9 gallons; 11 hours at 50% load on 7.9 gallons.
›How long will a iGen12000DFc run on propane (lp)?
Westinghouse's published figure: 9 hours at 25% load on a 20 lb propane tank; 5 hours at 50% load on a 20 lb propane tank.
›Which iGen12000DFc does this page cover?
the iGen12000DFc dual fuel inverter only — not the iGen11000DFc. Westinghouse's spec table lists it as dual fuel (gasoline and propane); this page does not assign a natural gas rating. Output: gasoline 9,000 watts running / 12,000 watts starting; propane (lp) 8,100 watts running / 11,000 watts starting.
Similar generators
- Westinghouse iGen11000DFc (11023) — 9,000 watts running
- Predator 11,500 Watt Tri-Fuel Super Quiet Inverter (72614) — 9,000 watts running
- Predator 9500 Super Quiet Inverter (71365) — 7,600 watts running
- Westinghouse iGen5000DFc — 3,900 watts running
Browse the full Generator Runtime Database or use the main Generator Runtime Calculator.