Predator 11500 published runtime
- Gasoline: 14 hours at 25% load on 6.8 gallons
- Propane (LP): 14.5 hours at 25% load on a 40 lb propane tank; 36.2 hours at 25% load on a 100 lb propane tank
- Natural gas: no runtime limit published — runs as long as the gas supply continues
Harbor Freight tested propane on two tank sizes. They are kept separate: a 40 lb tank uses the 40 lb figure and a 100 lb tank the 100 lb figure. On natural gas, runtime depends on a continued gas supply; no runtime limit is published.
Verified specifications
- Manufacturer
- Predator
- Model
- 11,500 Watt Tri-Fuel Super Quiet Inverter
- Model number
- 72614
- Model codes
- Predator / 11500 / 11,500 / item / 72614
- Generator type
- Inverter / Tri-Fuel
- Gasoline: running
- 9,000 watts
- Gasoline: starting / max
- 11,500 watts
- Gasoline: tank
- 6.8 gallons
- Gasoline: published runtime
- 14 hours at 25% load on 6.8 gallons
- Propane (LP): running
- 8,100 watts
- Propane (LP): starting / max
- 11,500 watts
- Propane (LP): published runtime
- 14.5 hours at 25% load on a 40 lb propane cylinder
- Propane (LP): published runtime
- 36.2 hours at 25% load on a 100 lb propane cylinder
- Natural gas: running
- 7,200 watts
- Natural gas: starting / max
- 11,500 watts
- Voltage
- 120/240V
- Engine
- Predator 458cc
- Displacement
- 458cc
- Noise
- 64.5 dB(A) at 25% load, 23 ft
- Starting system
- Remote and push-button start
- CO safety
- CO SECURE
- Outlets
- (2) 120V 20A GFCI; (1) 120V 30A L5-30R twist-lock; (1) 120/240V 30A L14-30R twist-lock; (1) 120/240V 50A 14-50R; (1) USB-A, (1) USB-C
Source: Harbor Freight owner's manual & product page, item 72614 — View Harbor Freight Specifications ↗
Specifications verified: September 28, 2026
Which model this page covers
This page covers the 11,500 W Tri-Fuel Super Quiet Inverter, item 72614 (49-state), with remote start and CO SECURE. It is a different generator from the Predator 9500 and Predator 13000.
Manufacturer figures vs. our estimates
Only the runtimes listed above are Harbor Freight's own published figures. When your load and fuel amount exactly match one of them, the calculator labels the result Manufacturer Published Runtime. Loads between published figures are labeled Estimated from Manufacturer Data, and loads outside the published range are labeled Extrapolated with a wider range. Those are GeneratorRuntime estimates, not Harbor Freight specifications.
What the Predator 11500's outlets let you connect
Based on the outlets Harbor Freight lists for this model. An outlet's amp rating is the most that one outlet can carry; the total from all outlets together can never exceed the generator's rated running watts.
- A 14-50R 50-amp outlet: accepts a 50-amp RV cord or a 50-amp generator cord to a properly installed transfer switch or inlet box. The 50-amp rating is the outlet's limit, not the generator's — power through it is still capped at the generator's rated running watts.
- A 30-amp 120/240V four-prong locking outlet: the usual connection for a 30-amp manual transfer switch or interlock inlet installed by an electrician, and the outlet needed for 240V equipment such as a well pump.
- A 120V 30-amp locking outlet: for a heavy single 120V load or a 30-amp RV with the correct adapter.
- GFCI-protected household outlets: test the GFCI before each use, as the manual instructs.
- Low-voltage DC or USB ports for charging small devices without an inverter adapter.
Outlet types are from Harbor Freight's product page or owner's manual. Powering home circuits requires a properly installed transfer switch or interlock — have a licensed electrician do it. Never plug a generator into a wall outlet ("backfeeding"): it can electrocute utility workers and neighbors and start fires.
Outage fuel planning for the Predator 11500
Dividing each of Harbor Freight's published runtimes by the fuel it was measured on gives an average burn rate. Each row assumes the generator runs continuously, around the clock, at exactly the load of that published figure: 24 hours = rate × 24, 72 hours = rate × 72, refills per day = 24 ÷ published runtime. These are GeneratorRuntime calculations from Harbor Freight's figures, not Harbor Freight specifications. Real outage use with appliances cycling on and off, or running the generator in intervals, usually needs less.
| Published point | Burn rate | 24 hours | 72 hours | Refills / day |
|---|---|---|---|---|
| Gasoline, 25% load: 14 h on 6.8 gal | ≈ 0.49 gal/h | ≈ 11.7 gal | ≈ 35.0 gal | ≈ 1.7 |
| Propane (LP), 25% load: 14.5 h on 40 lb | ≈ 2.76 lb/h | ≈ 66.2 lb | ≈ 198.6 lb | ≈ 1.7 |
| Propane (LP), 25% load: 36.2 h on 100 lb | ≈ 2.76 lb/h | ≈ 66.3 lb | ≈ 198.9 lb | under 1 |
Predator 11500 compared with similar generators
Figures below are each manufacturer's own published numbers for its first-listed fuel. Runtimes are shown at 25% load where the manufacturer publishes one; rows marked "different load" are not directly comparable. Tank sizes differ too, so use the calculator with each model for a like-for-like estimate at your load.
| Model | Running | Fuels | Tank | Published runtime |
|---|---|---|---|---|
| Predator 11,500 Watt Tri-Fuel Super Quiet Inverter (72614) | 9,000 W | Gasoline / Propane (LP) / Natural gas | 6.8 gal | 14 h @ 25% load |
| Westinghouse iGen11000DFc (11023) | 9,000 W | Gasoline / Propane (LP) | 7.92 gal | 17 h @ 25% load |
| Westinghouse iGen12000DFc | 9,000 W | Gasoline / Propane (LP) | 7.9 gal | 19 h @ 25% load |
| Predator 9500 Super Quiet Inverter (71365) | 7,600 W | Gasoline | 6.6 gal | 18.5 h @ 25% load |
| Predator 5000 Dual-Fuel Super Quiet Inverter (71367) | 3,900 W | Gasoline / Propane (LP) | 3.7 gal | 18.3 h @ 25% load |
What Harbor Freight's published data doesn't cover
For the Predator 11500, the verified manufacturer data we used does not include:
- a gasoline runtime at 50% load
- a propane (lp) runtime at 50% load
- any natural gas runtime
- a weight in our verified record
We leave these blank rather than guess. If you have an official Harbor Freight figure we're missing, tell us via the feedback link below.
The Predator 11500's CO SECURE feature is not a substitute for safe placement — see the carbon monoxide warning above.
Predator 11500 FAQ
›How long will a Predator 11500 run on gasoline?
Harbor Freight's published figure: 14 hours at 25% load on 6.8 gallons.
›How long will a Predator 11500 run on propane (lp)?
Harbor Freight's published figure: 14.5 hours at 25% load on a 40 lb propane tank; 36.2 hours at 25% load on a 100 lb propane tank.
›How long will a Predator 11500 run on natural gas?
Harbor Freight's published figure: no runtime limit published — runs as long as the gas supply continues.
›Which Predator 11500 does this page cover?
the 11,500 W Tri-Fuel Super Quiet Inverter, item 72614 (49-state), with remote start and CO SECURE. It is a different generator from the Predator 9500 and Predator 13000. Output: gasoline 9,000 watts running / 11,500 watts starting; propane (lp) 8,100 watts running / 11,500 watts starting; natural gas 7,200 watts running / 11,500 watts starting.
Similar generators
- Westinghouse iGen11000DFc (11023) — 9,000 watts running
- Westinghouse iGen12000DFc — 9,000 watts running
- Predator 9500 Super Quiet Inverter (71365) — 7,600 watts running
- Predator 5000 Dual-Fuel Super Quiet Inverter (71367) — 3,900 watts running
- Predator 3500 Super Quiet Inverter (71358) — 3,000 watts running
- Predator 2500 Watt Super Quiet Inverter (72010) — 2,000 watts running
Browse the full Generator Runtime Database or use the main Generator Runtime Calculator.