Westinghouse WGen9500TFc published runtime
- Gasoline: 15 hours at 25% load and 10 hours at 50% load on 6.6 gallons
- Propane: 8.75 hours at 50% load (propane quantity not stated)
- Natural gas: no runtime published (continuous utility supply)
Verified specifications
- Manufacturer
- Westinghouse
- Model
- WGen9500TFc
- Model number
- 9537
- Model codes
- WGen9500TFc / EFI
- Generator type
- Conventional / Tri-Fuel
- Gasoline: running
- 9,500 watts
- Gasoline: starting / max
- 12,500 watts
- Gasoline: tank
- 6.6 gallons
- Gasoline: published runtime
- 15 hours at 25% load on 6.6 gallons
- Gasoline: published runtime
- 10 hours at 50% load on 6.6 gallons
- Propane (LP): running
- 8,500 watts
- Propane (LP): starting / max
- 11,200 watts
- Propane (LP): published runtime
- 8.75 hours at 50% load on propane amount not stated
- Natural gas: running
- 7,500 watts
- Natural gas: starting / max
- 9,500 watts
- Engine
- Westinghouse 457cc 4-stroke OHV, EFI
- Displacement
- 457cc
- Dry weight
- 222 lb
- Noise
- 74 dB(A)
- Starting system
- Electric, remote, recoil
- CO safety
- CO sensor
- Outlets
- (2) 120V 5-20R GFCI duplex; (1) L14-30R 30A; (1) 120/240V 14-50R 50A
Source: Westinghouse — WGen9500TFc EFI product page — View Westinghouse Specifications ↗
Specifications verified: September 28, 2026
How much gas does the WGen9500TFc use?
- At 25% load: 6.6 gal ÷ 15 h ≈ 0.44 gallons per hour
- At 50% load: 6.6 gal ÷ 10 h ≈ 0.66 gallons per hour
These are our calculations from Westinghouse's published tank size and runtimes, not Westinghouse figures.
Manufacturer figures vs. our estimates
Only the runtimes listed above are Westinghouse's own published figures. When your load and fuel amount exactly match one of them, the calculator labels the result Manufacturer Published Runtime. Loads between published figures are labeled Estimated from Manufacturer Data, and loads outside the published range are labeled Extrapolated with a wider range. Those are GeneratorRuntime estimates, not Westinghouse specifications.
What the Westinghouse WGen9500TFc's outlets let you connect
Based on the outlets Westinghouse lists for this model. An outlet's amp rating is the most that one outlet can carry; the total from all outlets together can never exceed the generator's rated running watts.
- A 14-50R 50-amp outlet: accepts a 50-amp RV cord or a 50-amp generator cord to a properly installed transfer switch or inlet box. The 50-amp rating is the outlet's limit, not the generator's — power through it is still capped at the generator's rated running watts.
- A 30-amp 120/240V four-prong locking outlet: the usual connection for a 30-amp manual transfer switch or interlock inlet installed by an electrician, and the outlet needed for 240V equipment such as a well pump.
- GFCI-protected household outlets: test the GFCI before each use, as the manual instructs.
Outlet types are from Westinghouse's product page or owner's manual. Powering home circuits requires a properly installed transfer switch or interlock — have a licensed electrician do it. Never plug a generator into a wall outlet ("backfeeding"): it can electrocute utility workers and neighbors and start fires.
Outage fuel planning for the Westinghouse WGen9500TFc
Dividing each of Westinghouse's published runtimes by the fuel it was measured on gives an average burn rate. Each row assumes the generator runs continuously, around the clock, at exactly the load of that published figure: 24 hours = rate × 24, 72 hours = rate × 72, refills per day = 24 ÷ published runtime. These are GeneratorRuntime calculations from Westinghouse's figures, not Westinghouse specifications. Real outage use with appliances cycling on and off, or running the generator in intervals, usually needs less.
| Published point | Burn rate | 24 hours | 72 hours | Refills / day |
|---|---|---|---|---|
| Gasoline, 25% load: 15 h on 6.6 gal | ≈ 0.44 gal/h | ≈ 10.6 gal | ≈ 31.7 gal | ≈ 1.6 |
| Gasoline, 50% load: 10 h on 6.6 gal | ≈ 0.66 gal/h | ≈ 15.8 gal | ≈ 47.5 gal | ≈ 2.4 |
Westinghouse WGen9500TFc compared with similar generators
Figures below are each manufacturer's own published numbers for its first-listed fuel. Runtimes are shown at 25% load where the manufacturer publishes one; rows marked "different load" are not directly comparable. Tank sizes differ too, so use the calculator with each model for a like-for-like estimate at your load.
| Model | Running | Fuels | Tank | Published runtime |
|---|---|---|---|---|
| Westinghouse WGen9500TFc (9537) | 9,500 W | Gasoline / Propane (LP) / Natural gas | 6.6 gal | 15 h @ 25% load |
| Westinghouse WGen9500 | 9,500 W | Gasoline | 6.6 gal | 12 h @ 25% load |
| Westinghouse WGen9500DF | 9,500 W | Gasoline / Propane (LP) | 6.6 gal | 12 h @ 25% load |
| DuroMax XP12000EH | 9,500 W | Gasoline / Propane (LP) | 8.3 gal | 19 h @ 25% load |
| Predator 13000 Tri-Fuel (71386) | 10,000 W | Gasoline / Propane (LP) / Natural gas | 10.7 gal | 12.1 h @ 50% load (different load) |
What Westinghouse's published data doesn't cover
For the Westinghouse WGen9500TFc, the verified manufacturer data we used does not include:
- a propane (lp) runtime at 25% load (estimates below the lowest published load are extrapolated)
- the propane tank size its propane runtime was measured on
- any natural gas runtime
We leave these blank rather than guess. If you have an official Westinghouse figure we're missing, tell us via the feedback link below.
The Westinghouse WGen9500TFc's CO sensor feature is not a substitute for safe placement — see the carbon monoxide warning above.
Westinghouse WGen9500TFc FAQ
›How long will a WGen9500TFc run on gasoline?
Westinghouse lists 15 hours at 25% load and 10 hours at 50% load on the 6.6-gallon tank.
›How long will a WGen9500TFc run on propane?
Westinghouse lists 8.75 hours at 50% load but does not state the propane quantity, so the calculator does not scale it to other tank sizes.
›How long will it run on natural gas?
Natural gas comes from a utility line, so there is no tank to run out. Westinghouse does not publish a natural-gas consumption figure for this model.
›Is this the same as the WGen9500 or WGen9500DF?
No. The WGen9500TFc (part number 9537) is the tri-fuel EFI model with a CO sensor: gasoline 9,500 watts running / 12,500 watts peak, propane 8,500 watts / 11,200 watts, natural gas 7,500 watts / 9,500 watts. The WGen9500 and WGen9500DF are different generators.
Similar generators
- Westinghouse WGen9500 — 9,500 watts running
- Westinghouse WGen9500DF — 9,500 watts running
- DuroMax XP12000EH — 9,500 watts running
- Predator 13000 Tri-Fuel (71386) — 10,000 watts running
- Westinghouse WGen10500DFc (10523) — 10,500 watts running
- Westinghouse WGen11500TFc — 11,500 watts running
- Westinghouse WGen11500DFc (11523) — 11,500 watts running
Browse the full Generator Runtime Database or use the main Generator Runtime Calculator.