WGen11500DFc published runtime
- Gasoline: 19 hours at 25% load on 9.5 gallons; 9.5 hours at 50% load on 9.5 gallons
- Propane (LP): 7 hours at 50% load on a 20 lb propane tank
From Westinghouse's official product information, checked September 28, 2026.
Verified specifications
- Manufacturer
- Westinghouse
- Model
- WGen11500DFc
- Model number
- 11523
- Model codes
- WGen11500DFc / part / 11523
- Generator type
- Conventional / Dual Fuel
- Gasoline: running
- 11,500 watts
- Gasoline: starting / max
- 14,500 watts
- Gasoline: tank
- 9.5 gallons
- Gasoline: published runtime
- 19 hours at 25% load on 9.5 gallons
- Gasoline: published runtime
- 9.5 hours at 50% load on 9.5 gallons
- Propane (LP): running
- 10,500 watts
- Propane (LP): starting / max
- 13,500 watts
- Propane (LP): published runtime
- 7 hours at 50% load on a 20 lb propane cylinder
- Voltage
- 120/240V
- Engine
- Westinghouse 550cc 4-stroke OHV, cast iron sleeve
- Displacement
- 550cc
- Dry weight
- 230 lb
- Noise
- 74 dB(A)
- Starting system
- Electric, remote, recoil
- CO safety
- CO sensor with automatic shutdown
- Outlets
- (2) 120V 5-20R GFCI duplex; (1) 120/240V L14-30R (transfer-switch ready); (1) 120/240V 14-50R; (2) USB
Source: Westinghouse — WGen11500DFc product page (part 11523) — View Westinghouse Specifications ↗
Specifications verified: September 28, 2026
Which model this page covers
This page covers the WGen11500DFc dual fuel (part 11523) only — not the tri-fuel WGen11500TFc, which has its own page. Westinghouse lists gasoline and propane output only for the DFc; this page does not assign a natural gas rating.
Manufacturer figures vs. our estimates
Only the runtimes listed above are Westinghouse's own published figures. When your load and fuel amount exactly match one of them, the calculator labels the result Manufacturer Published Runtime. Loads between published figures are labeled Estimated from Manufacturer Data, and loads outside the published range are labeled Extrapolated with a wider range. Those are GeneratorRuntime estimates, not Westinghouse specifications.
What the WGen11500DFc's outlets let you connect
Based on the outlets Westinghouse lists for this model. An outlet's amp rating is the most that one outlet can carry; the total from all outlets together can never exceed the generator's rated running watts.
- A 14-50R 50-amp outlet: accepts a 50-amp RV cord or a 50-amp generator cord to a properly installed transfer switch or inlet box. The 50-amp rating is the outlet's limit, not the generator's — power through it is still capped at the generator's rated running watts.
- A 30-amp 120/240V four-prong locking outlet: the usual connection for a 30-amp manual transfer switch or interlock inlet installed by an electrician, and the outlet needed for 240V equipment such as a well pump.
- GFCI-protected household outlets: test the GFCI before each use, as the manual instructs.
- Low-voltage DC or USB ports for charging small devices without an inverter adapter.
Outlet types are from Westinghouse's product page or owner's manual. Powering home circuits requires a properly installed transfer switch or interlock — have a licensed electrician do it. Never plug a generator into a wall outlet ("backfeeding"): it can electrocute utility workers and neighbors and start fires.
Outage fuel planning for the WGen11500DFc
Dividing each of Westinghouse's published runtimes by the fuel it was measured on gives an average burn rate. Each row assumes the generator runs continuously, around the clock, at exactly the load of that published figure: 24 hours = rate × 24, 72 hours = rate × 72, refills per day = 24 ÷ published runtime. These are GeneratorRuntime calculations from Westinghouse's figures, not Westinghouse specifications. Real outage use with appliances cycling on and off, or running the generator in intervals, usually needs less.
| Published point | Burn rate | 24 hours | 72 hours | Refills / day |
|---|---|---|---|---|
| Gasoline, 25% load: 19 h on 9.5 gal | ≈ 0.50 gal/h | ≈ 12.0 gal | ≈ 36.0 gal | ≈ 1.3 |
| Gasoline, 50% load: 9.5 h on 9.5 gal | ≈ 1.00 gal/h | ≈ 24.0 gal | ≈ 72.0 gal | ≈ 2.5 |
| Propane (LP), 50% load: 7 h on 20 lb | ≈ 2.86 lb/h | ≈ 68.6 lb | ≈ 205.7 lb | ≈ 3.4 |
WGen11500DFc compared with similar generators
Figures below are each manufacturer's own published numbers for its first-listed fuel. Runtimes are shown at 50% load where the manufacturer publishes one; rows marked "different load" are not directly comparable. Tank sizes differ too, so use the calculator with each model for a like-for-like estimate at your load.
| Model | Running | Fuels | Tank | Published runtime |
|---|---|---|---|---|
| Westinghouse WGen11500DFc (11523) | 11,500 W | Gasoline / Propane (LP) | 9.5 gal | 9.5 h @ 50% load |
| Westinghouse WGen11500TFc | 11,500 W | Gasoline / Propane (LP) / Natural gas | 9.5 gal | 9.5 h @ 50% load |
| DuroMax XP15000HXT | 12,000 W | Gasoline / Propane (LP) / Natural gas | — | 12 h @ 50% load |
| DuroMax XP13000EH | 10,500 W | Gasoline / Propane (LP) | 8.3 gal | 8 h @ 50% load |
| Westinghouse WGen10500DFc (10523) | 10,500 W | Gasoline / Propane (LP) | 9.5 gal | 9.5 h @ 50% load |
What Westinghouse's published data doesn't cover
For the WGen11500DFc, the verified manufacturer data we used does not include:
- a propane (lp) runtime at 25% load (estimates below the lowest published load are extrapolated)
We leave these blank rather than guess. If you have an official Westinghouse figure we're missing, tell us via the feedback link below.
The WGen11500DFc's CO sensor with automatic shutdown feature is not a substitute for safe placement — see the carbon monoxide warning above.
WGen11500DFc FAQ
›How long will a WGen11500DFc run on gasoline?
Westinghouse's published figure: 19 hours at 25% load on 9.5 gallons; 9.5 hours at 50% load on 9.5 gallons.
›How long will a WGen11500DFc run on propane (lp)?
Westinghouse's published figure: 7 hours at 50% load on a 20 lb propane tank.
›Which WGen11500DFc does this page cover?
the WGen11500DFc dual fuel (part 11523) only — not the tri-fuel WGen11500TFc, which has its own page. Westinghouse lists gasoline and propane output only for the DFc; this page does not assign a natural gas rating. Output: gasoline 11,500 watts running / 14,500 watts starting; propane (lp) 10,500 watts running / 13,500 watts starting.
Similar generators
- Westinghouse WGen11500TFc — 11,500 watts running
- DuroMax XP15000HXT — 12,000 watts running
- DuroMax XP13000EH — 10,500 watts running
- Westinghouse WGen10500DFc (10523) — 10,500 watts running
- Westinghouse WGen9500 — 9,500 watts running
- Westinghouse WGen9500DF — 9,500 watts running
- Westinghouse WGen9500TFc (9537) — 9,500 watts running
Browse the full Generator Runtime Database or use the main Generator Runtime Calculator.