Skip to content
GeneratorRuntime.com

Westinghouse WGen11500TFc Runtime Calculator

Verified Specs ✓

Estimate how long a Westinghouse WGen11500TFc will run based on your power load and available fuel, using Westinghouse's published specifications as the baseline.

Specifications checked against Westinghouse-published information. GeneratorRuntime.com has not tested this generator and is not affiliated with Westinghouse.

How long does a Westinghouse WGen11500TFc run?

Westinghouse publishes:

  • 19 hours at 25% load · gasoline, 9.5 gallons
  • 9.5 hours at 50% load · gasoline, 9.5 gallons
  • 7 hours at 50% load · propane (lp), a 20 lb propane cylinder

Actual runtime varies with load and operating conditions.

Choose your generator and we'll use verified published specifications as the starting point. We haven't tested these generators ourselves.

1Your generator

Westinghouse WGen11500TFc

Verified Specs ✓

The specifications shown were checked against a manufacturer-published source. This does not mean GeneratorRuntime.com tested or endorses this generator, that the manufacturer endorses this site, or that runtime is guaranteed.

Conventional / Tri-Fuel · View model runtime guide

  • Gasoline
  • 11,500 running watts
  • 14,500 starting watts
  • 9.5 gallon tank

Published runtime:

  • 19 hr @ 25% load on 9.5 gal
  • 9.5 hr @ 50% load on 9.5 gal

Source: Westinghouse View source ↗

Checked 2026-09-28

Can't find your generator?

2Fuel available

Generator tank capacity: 9.5 gal

gal

Pre-filled with a full tank — change it to what you actually have, including stored cans.

3Expected load
%

Percent of running watts. 50% is a common planning figure.

Runtime17–21 hoursDetails ↓

Westinghouse WGen11500TFc published runtime

  • Gasoline: 19 hours at 25% load and 9.5 hours at 50% load on 9.5 gallons
  • Propane: 7 hours at 50% load on a 20 lb tank
  • Natural gas: no runtime published (continuous utility supply)

The propane figure combines two statements on Westinghouse's current WGen11500TFc product page: the specification table lists 7 hours propane runtime at 50% load, and the feature text says up to 7 hours on a 20 lb propane tank.

Verified specifications

Manufacturer
Westinghouse
Model
WGen11500TFc
Generator type
Conventional / Tri-Fuel
Gasoline: running
11,500 watts
Gasoline: starting / max
14,500 watts
Gasoline: tank
9.5 gallons
Gasoline: published runtime
19 hours at 25% load on 9.5 gallons
Gasoline: published runtime
9.5 hours at 50% load on 9.5 gallons
Propane (LP): running
10,500 watts
Propane (LP): starting / max
13,500 watts
Propane (LP): published runtime
7 hours at 50% load on a 20 lb propane cylinder
Natural gas: running
9,500 watts
Natural gas: starting / max
12,000 watts
Engine
Westinghouse 550cc 4-stroke OHV
Displacement
550cc
Weight
230 lb
Starting system
Push-button electric start, remote key fob, recoil backup
CO safety
CO sensor with automatic shutdown
Outlet: Transfer-switch-ready
L14-30R 120/240V 30A
Outlet: 50A
14-50R 120/240V
Outlet: Household
(2) GFCI 5-20R duplex

Source: Westinghouse — View Westinghouse Specifications ↗
Specifications verified: September 28, 2026

How much gas does the WGen11500TFc use?

  • At 25% load: 9.5 gal ÷ 19 h = 0.50 gallons per hour
  • At 50% load: 9.5 gal ÷ 9.5 h = 1.00 gallons per hour

These are our calculations from Westinghouse's published tank size and runtimes, not Westinghouse figures.

Transfer switch outlets

Westinghouse lists an L14-30R 120/240V transfer-switch-ready outlet and a 14-50R 120/240V outlet. Connecting a generator to a home must follow local codes and the manufacturer's instructions, using a qualified electrician where required.

Manufacturer figures vs. our estimates

Only the runtimes listed above are Westinghouse's own published figures. When your load and fuel amount exactly match one of them, the calculator labels the result Manufacturer Published Runtime. Loads between published figures are labeled Estimated from Manufacturer Data, and loads outside the published range are labeled Extrapolated with a wider range. Those are GeneratorRuntime estimates, not Westinghouse specifications.

What the Westinghouse WGen11500TFc's outlets let you connect

Based on the outlets Westinghouse lists for this model. An outlet's amp rating is the most that one outlet can carry; the total from all outlets together can never exceed the generator's rated running watts.

  • A 14-50R 50-amp outlet: accepts a 50-amp RV cord or a 50-amp generator cord to a properly installed transfer switch or inlet box. The 50-amp rating is the outlet's limit, not the generator's — power through it is still capped at the generator's rated running watts.
  • A 30-amp 120/240V four-prong locking outlet: the usual connection for a 30-amp manual transfer switch or interlock inlet installed by an electrician, and the outlet needed for 240V equipment such as a well pump.
  • GFCI-protected household outlets: test the GFCI before each use, as the manual instructs.

Outlet types are from Westinghouse's product page or owner's manual. Powering home circuits requires a properly installed transfer switch or interlock — have a licensed electrician do it. Never plug a generator into a wall outlet ("backfeeding"): it can electrocute utility workers and neighbors and start fires.

Outage fuel planning for the Westinghouse WGen11500TFc

Dividing each of Westinghouse's published runtimes by the fuel it was measured on gives an average burn rate. Each row assumes the generator runs continuously, around the clock, at exactly the load of that published figure: 24 hours = rate × 24, 72 hours = rate × 72, refills per day = 24 ÷ published runtime. These are GeneratorRuntime calculations from Westinghouse's figures, not Westinghouse specifications. Real outage use with appliances cycling on and off, or running the generator in intervals, usually needs less.

Published pointBurn rate24 hours72 hoursRefills / day
Gasoline, 25% load: 19 h on 9.5 gal≈ 0.50 gal/h≈ 12.0 gal≈ 36.0 gal≈ 1.3
Gasoline, 50% load: 9.5 h on 9.5 gal≈ 1.00 gal/h≈ 24.0 gal≈ 72.0 gal≈ 2.5
Propane (LP), 50% load: 7 h on 20 lb≈ 2.86 lb/h≈ 68.6 lb≈ 205.7 lb≈ 3.4

Westinghouse WGen11500TFc compared with similar generators

Figures below are each manufacturer's own published numbers for its first-listed fuel. Runtimes are shown at 50% load where the manufacturer publishes one; rows marked "different load" are not directly comparable. Tank sizes differ too, so use the calculator with each model for a like-for-like estimate at your load.

ModelRunningFuelsTankPublished runtime
Westinghouse WGen11500TFc11,500 WGasoline / Propane (LP) / Natural gas9.5 gal9.5 h @ 50% load
Westinghouse WGen11500DFc (11523)11,500 WGasoline / Propane (LP)9.5 gal9.5 h @ 50% load
DuroMax XP15000HXT12,000 WGasoline / Propane (LP) / Natural gas—12 h @ 50% load
DuroMax XP13000EH10,500 WGasoline / Propane (LP)8.3 gal8 h @ 50% load
Westinghouse WGen10500DFc (10523)10,500 WGasoline / Propane (LP)9.5 gal9.5 h @ 50% load

What Westinghouse's published data doesn't cover

For the Westinghouse WGen11500TFc, the verified manufacturer data we used does not include:

  • a propane (lp) runtime at 25% load (estimates below the lowest published load are extrapolated)
  • any natural gas runtime

We leave these blank rather than guess. If you have an official Westinghouse figure we're missing, tell us via the feedback link below.

The Westinghouse WGen11500TFc's CO sensor with automatic shutdown feature is not a substitute for safe placement — see the carbon monoxide warning above.

Westinghouse WGen11500TFc FAQ

›How long will a Westinghouse WGen11500TFc run on gasoline?

Westinghouse lists 19 hours at 25% load and 9.5 hours at 50% load on the 9.5-gallon tank.

›How long will a WGen11500TFc run on propane?

Westinghouse lists 7 hours at 50% load on a 20 lb propane tank. Other loads are extrapolated by the calculator and labeled as such.

›How long will it run on natural gas?

Natural gas comes from a utility line, so there is no tank to run out. Westinghouse does not publish a natural-gas consumption figure for this model.

›How many watts does the WGen11500TFc produce?

Gasoline: 11,500 watts running / 14,500 watts peak. Propane: 10,500 watts / 13,500 watts. Natural gas: 9,500 watts / 12,000 watts.

Similar generators

Browse the full Generator Runtime Database or use the main Generator Runtime Calculator.