Westinghouse WGen11500TFc published runtime
- Gasoline: 19 hours at 25% load and 9.5 hours at 50% load on 9.5 gallons
- Propane: 7 hours at 50% load on a 20 lb tank
- Natural gas: no runtime published (continuous utility supply)
The propane figure combines two statements on Westinghouse's current WGen11500TFc product page: the specification table lists 7 hours propane runtime at 50% load, and the feature text says up to 7 hours on a 20 lb propane tank.
Verified specifications
- Manufacturer
- Westinghouse
- Model
- WGen11500TFc
- Generator type
- Conventional / Tri-Fuel
- Gasoline: running
- 11,500 watts
- Gasoline: starting / max
- 14,500 watts
- Gasoline: tank
- 9.5 gallons
- Gasoline: published runtime
- 19 hours at 25% load on 9.5 gallons
- Gasoline: published runtime
- 9.5 hours at 50% load on 9.5 gallons
- Propane (LP): running
- 10,500 watts
- Propane (LP): starting / max
- 13,500 watts
- Propane (LP): published runtime
- 7 hours at 50% load on a 20 lb propane cylinder
- Natural gas: running
- 9,500 watts
- Natural gas: starting / max
- 12,000 watts
- Engine
- Westinghouse 550cc 4-stroke OHV
- Displacement
- 550cc
- Weight
- 230 lb
- Starting system
- Push-button electric start, remote key fob, recoil backup
- CO safety
- CO sensor with automatic shutdown
- Outlet: Transfer-switch-ready
- L14-30R 120/240V 30A
- Outlet: 50A
- 14-50R 120/240V
- Outlet: Household
- (2) GFCI 5-20R duplex
Source: Westinghouse — View Westinghouse Specifications ↗
Specifications verified: September 28, 2026
How much gas does the WGen11500TFc use?
- At 25% load: 9.5 gal ÷ 19 h = 0.50 gallons per hour
- At 50% load: 9.5 gal ÷ 9.5 h = 1.00 gallons per hour
These are our calculations from Westinghouse's published tank size and runtimes, not Westinghouse figures.
Transfer switch outlets
Westinghouse lists an L14-30R 120/240V transfer-switch-ready outlet and a 14-50R 120/240V outlet. Connecting a generator to a home must follow local codes and the manufacturer's instructions, using a qualified electrician where required.
Manufacturer figures vs. our estimates
Only the runtimes listed above are Westinghouse's own published figures. When your load and fuel amount exactly match one of them, the calculator labels the result Manufacturer Published Runtime. Loads between published figures are labeled Estimated from Manufacturer Data, and loads outside the published range are labeled Extrapolated with a wider range. Those are GeneratorRuntime estimates, not Westinghouse specifications.
What the Westinghouse WGen11500TFc's outlets let you connect
Based on the outlets Westinghouse lists for this model. An outlet's amp rating is the most that one outlet can carry; the total from all outlets together can never exceed the generator's rated running watts.
- A 14-50R 50-amp outlet: accepts a 50-amp RV cord or a 50-amp generator cord to a properly installed transfer switch or inlet box. The 50-amp rating is the outlet's limit, not the generator's — power through it is still capped at the generator's rated running watts.
- A 30-amp 120/240V four-prong locking outlet: the usual connection for a 30-amp manual transfer switch or interlock inlet installed by an electrician, and the outlet needed for 240V equipment such as a well pump.
- GFCI-protected household outlets: test the GFCI before each use, as the manual instructs.
Outlet types are from Westinghouse's product page or owner's manual. Powering home circuits requires a properly installed transfer switch or interlock — have a licensed electrician do it. Never plug a generator into a wall outlet ("backfeeding"): it can electrocute utility workers and neighbors and start fires.
Outage fuel planning for the Westinghouse WGen11500TFc
Dividing each of Westinghouse's published runtimes by the fuel it was measured on gives an average burn rate. Each row assumes the generator runs continuously, around the clock, at exactly the load of that published figure: 24 hours = rate × 24, 72 hours = rate × 72, refills per day = 24 ÷ published runtime. These are GeneratorRuntime calculations from Westinghouse's figures, not Westinghouse specifications. Real outage use with appliances cycling on and off, or running the generator in intervals, usually needs less.
| Published point | Burn rate | 24 hours | 72 hours | Refills / day |
|---|---|---|---|---|
| Gasoline, 25% load: 19 h on 9.5 gal | ≈ 0.50 gal/h | ≈ 12.0 gal | ≈ 36.0 gal | ≈ 1.3 |
| Gasoline, 50% load: 9.5 h on 9.5 gal | ≈ 1.00 gal/h | ≈ 24.0 gal | ≈ 72.0 gal | ≈ 2.5 |
| Propane (LP), 50% load: 7 h on 20 lb | ≈ 2.86 lb/h | ≈ 68.6 lb | ≈ 205.7 lb | ≈ 3.4 |
Westinghouse WGen11500TFc compared with similar generators
Figures below are each manufacturer's own published numbers for its first-listed fuel. Runtimes are shown at 50% load where the manufacturer publishes one; rows marked "different load" are not directly comparable. Tank sizes differ too, so use the calculator with each model for a like-for-like estimate at your load.
| Model | Running | Fuels | Tank | Published runtime |
|---|---|---|---|---|
| Westinghouse WGen11500TFc | 11,500 W | Gasoline / Propane (LP) / Natural gas | 9.5 gal | 9.5 h @ 50% load |
| Westinghouse WGen11500DFc (11523) | 11,500 W | Gasoline / Propane (LP) | 9.5 gal | 9.5 h @ 50% load |
| DuroMax XP15000HXT | 12,000 W | Gasoline / Propane (LP) / Natural gas | — | 12 h @ 50% load |
| DuroMax XP13000EH | 10,500 W | Gasoline / Propane (LP) | 8.3 gal | 8 h @ 50% load |
| Westinghouse WGen10500DFc (10523) | 10,500 W | Gasoline / Propane (LP) | 9.5 gal | 9.5 h @ 50% load |
What Westinghouse's published data doesn't cover
For the Westinghouse WGen11500TFc, the verified manufacturer data we used does not include:
- a propane (lp) runtime at 25% load (estimates below the lowest published load are extrapolated)
- any natural gas runtime
We leave these blank rather than guess. If you have an official Westinghouse figure we're missing, tell us via the feedback link below.
The Westinghouse WGen11500TFc's CO sensor with automatic shutdown feature is not a substitute for safe placement — see the carbon monoxide warning above.
Westinghouse WGen11500TFc FAQ
›How long will a Westinghouse WGen11500TFc run on gasoline?
Westinghouse lists 19 hours at 25% load and 9.5 hours at 50% load on the 9.5-gallon tank.
›How long will a WGen11500TFc run on propane?
Westinghouse lists 7 hours at 50% load on a 20 lb propane tank. Other loads are extrapolated by the calculator and labeled as such.
›How long will it run on natural gas?
Natural gas comes from a utility line, so there is no tank to run out. Westinghouse does not publish a natural-gas consumption figure for this model.
›How many watts does the WGen11500TFc produce?
Gasoline: 11,500 watts running / 14,500 watts peak. Propane: 10,500 watts / 13,500 watts. Natural gas: 9,500 watts / 12,000 watts.
Similar generators
- Westinghouse WGen11500DFc (11523) — 11,500 watts running
- DuroMax XP15000HXT — 12,000 watts running
- DuroMax XP13000EH — 10,500 watts running
- Westinghouse WGen10500DFc (10523) — 10,500 watts running
- Westinghouse WGen9500 — 9,500 watts running
- Westinghouse WGen9500DF — 9,500 watts running
- Westinghouse WGen9500TFc (9537) — 9,500 watts running
Browse the full Generator Runtime Database or use the main Generator Runtime Calculator.